UPS Systems
We are leading suppliers of UPS’s and various power electronics equipment’s. We had supplied UPS systems for multifarious and very demanding applications.
We supply UPS’s with standard specifications and also for specifications which are suitable to the customer requirements in various configurations and ratings.
Our UPS range is from 1 KVA to 100 KVA in single phase output and up to 4800 KVA in 3 phase output.
We offer latest IGBT/MOSFET based state of art technology employing instantaneous sine wave PWM controlled. We are committed to the quality norms not only during supply process but even after while rendering after sales services.
Interruption of Class is Incorrect like that Interruption of Powercut is Incorrect. For Example) If you are attending online classes at your home computer, you need to prevent power cuts during class time. Finally, you can choose the best
ups dealers in Chennai to buy ups for home computers.
UPS Technical Specification :
Sl.No |
Specification / Feature |
Standard Parameter |
1 |
Technology |
True Online Double Conversion design (DSP / Microprocessor based) |
2 |
Input Voltage Range |
160V - 270V for 1 Phase Input, 335V to 477V for 3Phase input |
3 |
Input Power factor |
Near Unity power factor |
4 |
Generator Compatibility |
Yes (1.2 times the UPS rating) |
5 |
Input frequency range |
47 - 53 Hz |
6 |
Rectifier type |
Advanced Rectifier with inbuilt APFC (Active Power Factor Corrector) for 1 phase and IGBT Charger advance rectifier with inbuilt APFC for 3phase |
7 |
Output Voltage |
230V AC +/- 1% for 1phase output and 400V AC (380/415V Selectable) for 3phase |
8 |
Total Harmonic Distortion |
1 phase output < 3% for Linear load < 5% for Non linear load and 3 phase output < 2% for Linear load < 5% for Non-Linear load |
9 |
Overload Capacity |
110% for 10sec & 130% for 2sec for 1&2kva UPS and 125% for 10min & 150% for 60sec for 3 to 60KVA UPS |
10 |
Inverter |
IGBT based PWM with Digital Control (Microprocessor based) |
11 |
Crest factor |
3:01 |
12 |
Static Bypass |
Automatic bypass switch facility |
13 |
Display |
Input Voltage, DC Voltage, Battery Voltage, Output Voltage, Output Power, Battery Charge %, Load % |
14 |
Output Powerfactor |
0.8 lag to Unity within KVA & KW rating |
15 |
Load in terms of PC per KVA (PC with 15" CFT monitor) |
3 PC per KVA (for 1 & 2KVA UPS) 5PC per KVA (for 3 to 60KVA) |
16 |
Battery Type |
SMF / Tubular |
17 |
Battery Charger Current limit |
6A for 1& 2KVA, 4 to 8A for 3&5KVA, 4 to 20A upto 60KVA |
18 |
Ambient Temperatur |
45˚ C |
19 |
Noise Level |
< 50 db @ 3 meter |
20 |
Testing Standard |
IEC 62040 part III |
21 |
Galvanic isolation |
Isolation transformer provided |
Battery Back-up Time - Sample :
UPS KVA rating |
DC Voltage |
Output Power factor |
No. of 12V SMF batteries |
Battery back up Period |
|
|
|
|
15min |
30min |
1hour |
2hour |
3hour |
1 KVA |
36V |
0.7 |
3 |
17AH |
2x17AH |
42AH |
65AH |
100AH |
2KVA |
96V |
0.7 |
8 |
17AH |
26AH |
42AH |
65AH |
100AH |
3KVA |
192V |
0.8 |
16 |
17AH |
17AH |
26AH |
42AH |
65AH |
5 / 6 KVA |
192V |
0.8 |
16 |
17AH |
26AH |
42AH |
65AH |
100AH |
8KVA |
240V |
0.8 |
20 |
17AH |
26AH |
42AH |
100AH |
2x65AH |
10KVA |
240V |
0.8 |
20 |
26AH |
42AH |
65AH |
2x65AH |
2x100AH |
- The batteries considered are of Sealed Maintenance free type (SMF)
- SMF batteries needs to be installed in ambient temperature of 20˚C to 25˚C
- The UPS is considered to be working @ 90% of its load capacity